Head Office: Spain: Tel: +34 983 549 900
Offices In Europe: Spain: +34 983 54 99 00 | France: +33 975 181 356
Poland Plastics: +48 223 071 201

Used machine: Thermoformer QS GROUP SF-SV-22-13-06p - 2007

Data Sheet of Used QS GROUP SF-SV-22-13-06p

Ref. 300045595

Year: 2007

Brand: QS GROUP

Model: SF-SV-22-13-06p

Status: For sale

Delivery time: Immediate

Technical Specifications

Material : ABS, ASA, HIPS, PC, PE, PP, PMMA, PVC

Forming Area (Vxh): 2310x1360mm

Material Thickness (Min): 1 mm

Material Thickness (Max): 10 mm

Products Type: Container

Feeding Systems: Sheet fed

Other Specifications:

This single station thermoforming machine is designed and built to meet the requirements of various production sectors, for small and medium production of thermoplastic materials with thicknesses ranging from 1 mm to 10 mm and maximum plate dimensions up to 2310 x 1360 mm.
This is a machine in very good working condition.

List of supported materials:
ABS (acrylonitrile butadiene styrene).
ASA (acrylonitrile butadiene butadiene ester acrylic)
HIPS (high impact polystyrene)
PC (polycarbonate)
PE (high and low density polyethylene)
PP (polypropylene)
PMMA (acrylic)
PVC
Double laminated plastic
Coextruded plastic.

Plate loading and unloading of the product: Manual

Mold table:
Maximum stroke: 970 mm
Maximum mold height: 600 mm
Mold base height: 195 mm
Clamping force: 27 kN
Included: Stroke control with linear transducer, vacuum line for part forming, water line for mold thermoregulation and air line for critical demolding zone devices.

Closing frame:
Maximum plate: 2310 x 1360 mm.
Maximum opening with manual load: 650 mm
Closing force: 35 kN

Cooling electric fans: 6 Fans with a motor power of 0,55 kW each.

Heating panels:
Upper panel power: 76,05 Kw
Resistances (ceramic): 117 of 650 W
Power lower panel: 46,8 Kw
Resistors (ceramic): 117 of 400 W

Counter mold:
Maximum stroke: 1000 mm
Maximum height of counter-mold: 700 mm
Closing force: 12 kN

Vacuum system
Tank capacity: 1300 l
Pump flow rate: 200 M3 / h
Motor power: 4 KW

Air system:
Operating pressure: 6 (+/-10%) bar
Maximum absorption (approx.): 1100 Nlt/cycle
Water system:
Operating pressure: 2,5 (+/- 10%) bar
Consumption: 0.8 M3 / h

Heating system control
Upper panel with percentage regulation of each heating element
Lower panel with regulation in percentage of each pair of heaters

Thermoforming cycles / software
Standard: negative/positive forming, with/without counterforming

Protections and safety standards
Standard manufacturing and safety standards. Directive: 89/336 - 98/37/CE - 73/23 - en 12409/2001 and EN 292 standard.

Other Details:

Guarantee: Without guarantee

Current condition: Not running. Can be shown with material

Availability: Immediate